Revision 3-26-2012 Page |
10
The UDP data to be sent consists of 7 HEX codes that will be transmitted to the designated IP address and Port.
The format is shown below.
SEND CMD FORMAT: X1 X2 X3 X4 X5 X6 X7 (X# is the Value in HEX)
EXAMPLE
SEND CMD: 01 FE 11 FF 00 00 00 ( The unit would be powered ON)
For testing purposes, feel free to use a UDP Test program to verify operation of the amplifier once set up. An
example of a free tool available online that is useful is the UDP Test Tool from Simple Com Tools.
Available at: http://www.simplecomtools.com/ProductCart/pc/viewPrd.asp?idproduct=6&idcategory=5
XML Status Monitoring
Real time status monitoring can be done by an external control system via the status.xml file available on the
amplifier. Many modern external control systems have means of reading and parsing xml files. The XML file can
be found at this address on the amplifier:
http:// IP ADDRESS/status.xml Example: http://192.168.1.240/status.xml
The XML format is contains three levels of information: 1) Identifies this product as an amplifier, 2) Identifies the
Model of Product, and 3) Provides low level status information about individual parameters key to the system. An
example of the format is shown here:
<AMP>
<A2007>
<TYPE>SYSTEM</TYPE>
<TITLE>System Power Stat:</TITLE>
<DATA>0</DATA>
</A2007>
<A2007>
<TYPE>SYSTEM</TYPE>
<TITLE>System Mute Stat:</TITLE>
<DATA>0</DATA>
</A2007>
<A2007>
<TYPE>CH1</TYPE>
<TITLE>CH 1 Temp:</TITLE>
<DATA>37</DATA>
</A2007>
</AMP>